(Summary description)When the unit is running normally, the controller will monitor the oil pressure, motor current and other parameters of the system. Once any problem occurs, the control system will automatically take corresponding measures to protect the unit and display the fault information on the unit screen.

Operation process of Water Chiller Manufacturers china

(Summary description)When the unit is running normally, the controller will monitor the oil pressure, motor current and other parameters of the system. Once any problem occurs, the control system will automatically take corresponding measures to protect the unit and display the fault information on the unit screen.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-05-16
  • Views:0
Information

Do you know the operation process of Water Chiller Manufacturers china? Let’s take a look at it briefly below!
1. Preparations before starting
1. Make sure the power of the unit and controller is connected.
2. Confirm that the cooling tower fan, cooling water pump, and cold water pump are all turned on.
3. Confirm that the end fan coil units are powered on.
2. Start
1. Press the status key on the keyboard, and then switch the unit ON/OFF toggle switch below the keyboard to the ON position.
2. The unit will perform a self-check, after a few seconds, one compressor will start, and the other compressor will start after the load increases.
3. Once the unit is started, all operations are automatic, and the unit will automatically start and stop according to the change of cooling load (chilled water supply and return water temperature).


3. Normal operation
1. When the unit is running normally, the controller will monitor the oil pressure, motor current and other parameters of the system. Once any problem occurs, the control system will automatically take corresponding measures to protect the unit and display the fault information on the unit screen.
2. In every 24-hour operating cycle, a special person shall permanently record the operating conditions of the unit at fixed time intervals.
Fourth, stop
1. As long as the unit ON/OFF toggle switch under the keyboard is switched to the off position, the unit can be stopped.
2. In order to prevent damage, do not cut off the power supply of the unit even when the unit is shut down.